WMV-2000 Veterinary Bone Drill system
Adantages
Excellent torque for prosthesis replacement surgery.
Powerful motors can provide the best speed and power.
Extended capacity battery ensure the implementation of efficient operation.
The main components are made of high-strength stainless steel.
Optional external power supply system.
Autaclavable.
Single and multi-function mode for selection.
2 years warranty period.
تفاصيل المنتج
Specification
Electric Handpiece:2100 Electric: Yes Multifunctional: Yes Weight (with battery): ≤1000 Grams Speed: 0-15000 rpm Power source: Battery Sterilizable: Autoclavable Battery:1001 Technology: Ni-Mh Insert/detachment method: The blocking mechanism: Yes Autoclavable Aseptic Transfer Kit:Yes Run time with battery: 30-40 min Battery Charger 1002-4 Simultaneously charged batteries: 4 Battery charge status: Indicator light Attachment Sagittal saw attachment: 2101 Oscillations (osc/min) 0-15000 Operation(V) voltage 14.4 Sterilization 135°C Noise(db) ≤75 Bone drill attachment: 2102/2102SAO Speed(r.p.m) 0-1000 Torque(Nm) 2.9 Operation(V) voltage 14.4 Sterilization 135°C Noise(db) ≤40 Canulate drill attachment:2103/2103B/2103D Speed(r.p.m) 0-630 Torque(Nm) 3.3 Operation(V) voltage 14.4 Sterilization 135°C Noise(db) ≤40 | Cranial drill attachment: 2104 Speed(r.p.m) 0-1000 Torque(Nm) 2.9 Operation(V) voltage 14.4 Sterilization 135°C Noise(db) ≤40 Cranial bur attachment: 2105 Speed(r.p.m) 0-40000 Sterilization 135°C The telescopic Noise(db) ≤40 Sternum saw attachment: 2106 Oscillations (osc/min) 0-15000 Operation(V) voltage 14.4 Sterilization 135°C Noise(db) ≤70 Acetabulum reaming drill attachment: 2107/2107B/2107D Speed(r.p.m) 0-280 Torque(Nm) 7.8 Operation(V) voltage 14.4 Sterilization 135°C Noise(db) ≤40 Reciprocating saw attachment 2109 Oscillations (osc/min) 0-15000 Operation(V) voltage 14.4 Sterilization 135°C Noise(db) ≤70 Torque limiter attachment 2110/2111 Torque(Nm) 4NM/1.5NM Operation(V) voltage 14.4 Sterilization 135°C Noise(db) ≤40 TPLO saw attachment 2112 Oscillations (osc/min) 0-15000 Operation(V) voltage 14.4 Sterilization 135°C Noise(db) ≤70 |
In the condition known as a cranial cruciate ligament rupture this may result in long cerrn degeneration,
whereby fibers within che ligarnenc weaken over tirne.
It is well known that when these ligarnencs rupture, che joint becomes unstable.
The de-generation may cause pain and can in sonne cases leads co chronic progressive arthritis.
T PLO saw attachment has been specifically designed for this type of application.
①2100 Multi - function handpiece
②2101 Sagitcal saw attachment
③2102 Bone drill attachrnenc
④2103 Cannulaced drill attachment
⑤2112 TPLO attachment
⑥Saw blade & TPLO blades (R:12-30mrn)